Paradox Alarm Control Control Host, PA-728/738ult/748
- Payment Type:
- T/T, L/C, Western Union, Paypal
- Min. Order:
- 20 Set/Sets
- Min. Order:
- 20 Set/Sets
- Delivery Time:
- 7 Days
- Transportation:
- Ocean, Land, Air
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | China |
---|---|
Productivity: | 5000PCS/week |
Supply Ability: | 100000 |
Payment Type: | T/T,L/C,Western Union,Paypal |
Certificate: | CE, UL |
Transportation: | Ocean,Land,Air |
Model PA-728
Introduction
4 zone inputs (8 zones with zone doubling) + 2 keypad zones
2 partitions
49 user codes
256 events buffered
1 PGM output
950mA switching power supply
Supervised bell output, auxiliary output and telephone line
Patented 2 opto coupler dialer circuit - the most reliable dialer in the industry
2-wire smoke detector input option (input 3)
Serial or parallel wiring for zone doubling connections
Master Code Lock: cannot change or delete the Master Code or User Code 01 Supports pager reporting
Closing Delinquency Timer: transmit a report when last arming exceeds timer
Auto-test report can now be set in hours or days
Introduction
4 zone inputs (8 zones with zone doubling) + 2 keypad zones
2 partitions
49 user codes
256 events buffered
1 PGM output
950mA switching power supply
Supervised bell output, auxiliary output and telephone line
Patented 2 opto coupler dialer circuit - the most reliable dialer in the industry (US Patents 5751803, RE39406)
2-wire smoke detector input option (input 3)
Serial or parallel wiring for zone doubling connections
Master Code Lock: cannot change or delete the Master Code or User Code 01
Supports pager reporting
Closing Delinquency Timer: transmit a report when last arming exceeds timer
Auto-test report can now be set in hours or days
Introduction
8 zone inputs (16 zones with zone doubling) + 2 keypad zones
1.1A switching power supply
CTR-21 approved dialer
2 partitions
49 user codes
256 events buffered
2 PGM outputs + 1 alarm relay
Supervised bell output, auxiliary output and telephone line
2-wire smoke detector input option (input 3)
Serial or parallel wiring for zone doubling connections
Master Code Lock: Cannot change or delete the Master Code or User Code 01
Supports pager reporting
Closing Delinquency Timer: Transmit a report when last arming exceeds timer
Auto-test report can now be set in hours or days
Timed Test Transmission feature
Includes 28cm x 28cm x 8cm (11" x 11" x 3") metal box
Model
PA-728+
PA-728ULT
PA-738ULT
Defense zones
8
8
10
2-wire smoke detector input option (input 3)
YES
YES
YES
Warranty
3-year
3-year
3-year
Set Weight(Panel&Keyboard)
150g
350g
410g
Related Keywords