UPS Power Rack Mount UPS1KVA-6KVA (Rack UPS TR Series)
- Payment Type:
- L/C, T/T, Western Union
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Shenzhen,Guangdong,China |
---|---|
Payment Type: | L/C, T/T, Western Union |
Product Description
Product Description
UPS Power Rack Mount UPS1KVA-6KVA
Features:
UPS's IP/OP: 110/115/120VAC 50/60Hz
UPS's IP/OP: 220/230/240VAC 50/60Hz
KEY FEATURES:
UPS's Wide input voltage range
UPS's Zero transfer time
UPS's Protection against all type of power problems
Self test while start of the UPS
UPS's Site wiring fault warning
On battery power-on function
Smart RS232 communication interface
Intelligent slot available
Sealed lead-acid, maintenance free battery
True online double conversion technology with advanced microprocessor control
APPLICATION:
Servers, Data-Center, Critical network devices, Sensitive electronic equipment, Telecom, etc.
TECHNICAL SPECIFICATION:
Model T1KR T1KRL T2KR T2KRL T3KR T3KRL T6KRL
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W 6KVA/4200W
Input Voltage (115~300)VAC (176~276)VAC
Frequency 46~54Hz/56~64Hz
Output Voltage 220/230/240(1± 1%)VAC
Frequency 50/60Hz(Adjustable)
50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode: 50Hz(1± 0.2%)
60Hz AC Mode: Follow AC Mode(AC Range 56~64Hz); Battery Mode: 60Hz(1± 0.2%)
Output Wave Form Sine Wave
Back-up Time Full Load ≥ 5' Depends on the capacity of the external batteries bank ≥ 9' Depends on the capacity of the external batteries bank ≥ 5' Depends on the capacity of the external batteries bank Depends on the capacity of the external batteries bank
Half Load ≥ 14' ≥ 21' ≥ 15'
Battery Nominal Voltage 36VDC 96VDC 240VDC
Transfer Time 0ms
Overload Capacity 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms 105%~130% 10min, over 150%1min
Communications RS-232+Intelligent Slot
Operating Environment Temperature 0C~40C
Humidity 15%~90%
Dimensions(W*D*H)mm 482.6*450*88 482.6*600*130
Net Weight(Kg) 16 9 10.5 11.5 11 12.5 19.5
Features:
UPS's IP/OP: 110/115/120VAC 50/60Hz
UPS's IP/OP: 220/230/240VAC 50/60Hz
KEY FEATURES:
UPS's Wide input voltage range
UPS's Zero transfer time
UPS's Protection against all type of power problems
Self test while start of the UPS
UPS's Site wiring fault warning
On battery power-on function
Smart RS232 communication interface
Intelligent slot available
Sealed lead-acid, maintenance free battery
True online double conversion technology with advanced microprocessor control
APPLICATION:
Servers, Data-Center, Critical network devices, Sensitive electronic equipment, Telecom, etc.
TECHNICAL SPECIFICATION:
Model T1KR T1KRL T2KR T2KRL T3KR T3KRL T6KRL
Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W 6KVA/4200W
Input Voltage (115~300)VAC (176~276)VAC
Frequency 46~54Hz/56~64Hz
Output Voltage 220/230/240(1± 1%)VAC
Frequency 50/60Hz(Adjustable)
50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode: 50Hz(1± 0.2%)
60Hz AC Mode: Follow AC Mode(AC Range 56~64Hz); Battery Mode: 60Hz(1± 0.2%)
Output Wave Form Sine Wave
Back-up Time Full Load ≥ 5' Depends on the capacity of the external batteries bank ≥ 9' Depends on the capacity of the external batteries bank ≥ 5' Depends on the capacity of the external batteries bank Depends on the capacity of the external batteries bank
Half Load ≥ 14' ≥ 21' ≥ 15'
Battery Nominal Voltage 36VDC 96VDC 240VDC
Transfer Time 0ms
Overload Capacity 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms 105%~130% 10min, over 150%1min
Communications RS-232+Intelligent Slot
Operating Environment Temperature 0C~40C
Humidity 15%~90%
Dimensions(W*D*H)mm 482.6*450*88 482.6*600*130
Net Weight(Kg) 16 9 10.5 11.5 11 12.5 19.5