General Meditech Inc.
General Meditech Inc.
Patient Monitor, Accurate Measurement, Ideal for ECGNew
  • Patient Monitor, Accurate Measurement, Ideal for ECGNew
Patient Monitor, Accurate Measurement, Ideal for ECGNew

Patient Monitor, Accurate Measurement, Ideal for ECGNew

Payment Type:
Telegraphic Transfer in Advance (Advance TT, T/T)
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: Telegraphic Transfer in Advance (Advance TT, T/T)
Product Description
Product Description
  • Huge history trend data storage: up to 360 hours
  • ECG:
    • Main/side stream (optional): Plug-and-play
    • Measurement range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
    • Accuracy: ±2mmHg
    • Respiration rate: 0 to 150BrPM
    • Accuracy: ±1BrPM
    • Input: 3/5 wires ECG cable
    • Lead section: I, II, III/ aVR, aVL and aVF/V
    • Gain section: x1/4, x1/2, x1, x2 and x4, automatic
    • Sweep speed: 6.25, 12.5, 25 and 50mm/s
    • Heart rate range: 15 to 380BPM
    • Calibration: ±1mV
    SpO2:
    • Display type: waveform, data
    • Measurement range: 0 to 100%
    • Accuracy: ± 2%
    • Pulse measurement range: 30 to 250BPM
    • Resolution: ±1BPM
    NIBP:
    • Philosophy: oscillometric method
    • Measurement type: adult, pediatric, neonate
    • Measurement parameter: systolic, diastolic and mean
    • Measurement method: manual, automatic and continuous measurement
    • Unit: mmHg/kPa selectable
    • Accuracy: ±2 or 3mmHg
    Temperature:
    • Number of channel: 2 channels
    • Resolution: 0.1°C
    • Display: T1, T2 and ΔT
    Respiration:
    • Thoracic impedance, nasal tube double
    • Method delectable
    • Measurement range: 0 to 120BPM
    • Accuracy: ±1BPM
    • Resolution: 1BPM
    ETCO2
  • Main/side stream (optional): Plug-and-play
  • Measurement range: 0 to 150mmHg (0 to 19.7%, 0 to 20kPa)
  • Accuracy: ±2mmHg
  • Respiration rate: 0 to 150BrPM
  • Accuracy: ±1BrPM
  • Input: 3/5 wires ECG cable
  • Lead section: I, II, III/ aVR, aVL and aVF/V
  • Gain section: x1/4, x1/2, x1, x2 and x4, automatic
  • Sweep speed: 6.25, 12.5, 25 and 50mm/s
  • Heart rate range: 15 to 380BPM
  • Calibration: ±1mV
  • Display type: waveform, data
  • Measurement range: 0 to 100%
  • Accuracy: ± 2%
  • Pulse measurement range: 30 to 250BPM
  • Resolution: ±1BPM
  • Philosophy: oscillometric method
  • Measurement type: adult, pediatric, neonate
  • Measurement parameter: systolic, diastolic and mean
  • Measurement method: manual, automatic and continuous measurement
  • Unit: mmHg/kPa selectable
  • Accuracy: ±2 or 3mmHg
  • Number of channel: 2 channels
  • Resolution: 0.1°C
  • Display: T1, T2 and ΔT
  • Thoracic impedance, nasal tube double
  • Method delectable
  • Measurement range: 0 to 120BPM
  • Accuracy: ±1BPM
  • Resolution: 1BPM
  • Send your message to this supplier

    • Ms.  Charlotte

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords