General Meditech Inc.
General Meditech Inc.
Patient Monitor, Accurate Measurement, ECG
  • Patient Monitor, Accurate Measurement, ECG
Patient Monitor, Accurate Measurement, ECG

Patient Monitor, Accurate Measurement, ECG

Payment Type:
Telegraphic Transfer in Advance (Advance TT, T/T)
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Payment Type: Telegraphic Transfer in Advance (Advance TT, T/T)
Product Description
Product Description
  • Features:
    • Drug calculation, ST segment detection, pace maker andarthythmia analysis
    • Five types of fixed display format includes OxyCRG diagram, 7 lead ECG waveform simultaneously and large font mode
    • Five types of user defined display format: display multi-channel real time waveform and trend diagram same time
    • Audible/visual alarm, apnea alarm available, alarm limits area djustable
    • WAN communication function to network with central monitoring system, make long distance monitoring, diagnosis, maintenance and software upgrade possible
    • Printing of data, waveform, trend table and trend diagram
    • Complete carting and mounting solution
  • Suitable for adults, pediatrics and neonates
  • Applications in bedside/delivery monitoring: widely used inpatient room, emergency room, PACU, ICU and CCU
  • Specifications:
    • Huge history trend data storage: up to 360 hours
    • ECG:
      • Input: 3/5 wires ECG cable
      • Lead section: I, II, III/ aVR, aVL, aVF/V
      • Gain section: x1/4, x1/2, x1, x2 and x4 and automatic
      • Sweep speed: 6.25, 12.5, 25 and 50mm/s
      • Heart rate range: 15-380BPM
      • Calibration: ±1mV
    • SpO2:
      • Display type: waveform, data
      • Measurement range: 0-100%
      • Accuracy: ± 2%
      • Pulse measurement range: 30-250BPM
      • Resolution: ±1BPM
    • NIBP:
      • Philosophy: oscillometric method
      • Measurement type: adult, pediatric, neonate
      • Measurement parameter: systolic, diastolic, mean
      • Measurement method: manual, automatic and continuousmeasurement
      • Unit: mmHg/kPa selectable
      • Accuracy: ±2 or 3mmHg
    • Temperature:
      • Number of channel: 2 channels
      • Resolution: 0.1°C
      • Display: T1, T2 and ΔT
    • Respiration:
      • Thoracic impedance, nasal tube double
      • Method delectable
      • Measurement range: 0-120BPM
      • Accuracy: ±1BPM
      • Resolution: 1BPM
    • ETCO2:
      • Main/side stream (optional): plug-and-play
      • Measurement range: 0-150mmHg (0-19.7%, 0-20kPa)
      • Accuracy: ±2mmHg
      • Respiration rate: 0-150BrPM
      • Accuracy: ±1BrPM
  • Drug calculation, ST segment detection, pace maker andarthythmia analysis
  • Five types of fixed display format includes OxyCRG diagram, 7 lead ECG waveform simultaneously and large font mode
  • Five types of user defined display format: display multi-channel real time waveform and trend diagram same time
  • Audible/visual alarm, apnea alarm available, alarm limits area djustable
  • WAN communication function to network with central monitoring system, make long distance monitoring, diagnosis, maintenance and software upgrade possible
  • Printing of data, waveform, trend table and trend diagram
  • Complete carting and mounting solution
  • Huge history trend data storage: up to 360 hours
  • ECG:
    • Input: 3/5 wires ECG cable
    • Lead section: I, II, III/ aVR, aVL, aVF/V
    • Gain section: x1/4, x1/2, x1, x2 and x4 and automatic
    • Sweep speed: 6.25, 12.5, 25 and 50mm/s
    • Heart rate range: 15-380BPM
    • Calibration: ±1mV
  • SpO2:
    • Display type: waveform, data
    • Measurement range: 0-100%
    • Accuracy: ± 2%
    • Pulse measurement range: 30-250BPM
    • Resolution: ±1BPM
  • NIBP:
    • Philosophy: oscillometric method
    • Measurement type: adult, pediatric, neonate
    • Measurement parameter: systolic, diastolic, mean
    • Measurement method: manual, automatic and continuousmeasurement
    • Unit: mmHg/kPa selectable
    • Accuracy: ±2 or 3mmHg
  • Temperature:
    • Number of channel: 2 channels
    • Resolution: 0.1°C
    • Display: T1, T2 and ΔT
  • Respiration:
    • Thoracic impedance, nasal tube double
    • Method delectable
    • Measurement range: 0-120BPM
    • Accuracy: ±1BPM
    • Resolution: 1BPM
  • ETCO2:
    • Main/side stream (optional): plug-and-play
    • Measurement range: 0-150mmHg (0-19.7%, 0-20kPa)
    • Accuracy: ±2mmHg
    • Respiration rate: 0-150BrPM
    • Accuracy: ±1BrPM
  • Input: 3/5 wires ECG cable
  • Lead section: I, II, III/ aVR, aVL, aVF/V
  • Gain section: x1/4, x1/2, x1, x2 and x4 and automatic
  • Sweep speed: 6.25, 12.5, 25 and 50mm/s
  • Heart rate range: 15-380BPM
  • Calibration: ±1mV
  • Display type: waveform, data
  • Measurement range: 0-100%
  • Accuracy: ± 2%
  • Pulse measurement range: 30-250BPM
  • Resolution: ±1BPM
  • Philosophy: oscillometric method
  • Measurement type: adult, pediatric, neonate
  • Measurement parameter: systolic, diastolic, mean
  • Measurement method: manual, automatic and continuousmeasurement
  • Unit: mmHg/kPa selectable
  • Accuracy: ±2 or 3mmHg
  • Number of channel: 2 channels
  • Resolution: 0.1°C
  • Display: T1, T2 and ΔT
  • Thoracic impedance, nasal tube double
  • Method delectable
  • Measurement range: 0-120BPM
  • Accuracy: ±1BPM
  • Resolution: 1BPM
  • Main/side stream (optional): plug-and-play
  • Measurement range: 0-150mmHg (0-19.7%, 0-20kPa)
  • Accuracy: ±2mmHg
  • Respiration rate: 0-150BrPM
  • Accuracy: ±1BrPM
  • Send your message to this supplier

    • Ms.  Charlotte

    • Enter between 20 to 4,000 characters.

    Related Keywords

    Related Keywords