Shenzhen Genor Power Equipment Co., Ltd.
Shenzhen Genor Power Equipment Co., Ltd.
20kw to 300kw Auto Start Diesel Generator Outdoor
  • 20kw to 300kw Auto Start Diesel Generator Outdoor
20kw to 300kw Auto Start Diesel Generator Outdoor

20kw to 300kw Auto Start Diesel Generator Outdoor

Payment Type:
L/C, T/T
Min. Order:
1 Set/Sets
Min. Order:
1 Set/Sets
Delivery Time:
25 Days
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: Guangdong, China (Mainland)
Supply Ability: 200 Set/Sets per Month
Payment Type: L/C,T/T
Product Description
Product Description
  20kw to 300kw Auto Start Diesel Generator Outdoor   The unique PT fuel system and four types of air absorbing methods (natural, pressure adding, midway cooling and double pressure adding) have been applied for the generator. It has the advantage of light weight, high power, strong torque, low oil cost and convenient maintenance ect, and has the function of self-protection. It can also be grouped to be automatic power generator sets.        
Genset Model Prime Power Standby Power Engine Fuel Consumption Cylinder No. Displacement Bore X Stroke
KW KVA KW KVA (g/kwh)  (L ) (mm)
GNRC23 16 20 18 22.5 4B3.9-G ≤229 4 3.9 102*120
GNRC30 20 25 24 30 4B3.9-G ≤229 4 3.9 102*120
GNRC35 24 30 28 35 4BT3.9-G ≤214 4 3.9 102*120
GNRC56 40 50 45 56 4BTA3.9-G ≤215 4 3.92 102*120
GNRC63 45 56 50 63 4BTA3.9-G ≤215 4 3.92 102*120
 GNRC70 50 63 56 70 6BT5.9G1 ≤215 6 5.88 102*120
GNRC106 78 98 85 106 6BT5.9G ≤215 6 5.88 102*120
GNRC125 90 113 100 125 6BT5.9G2 ≤215 6 5.88 102*120
GNRC150 104 130 120 150 6BT5.9G2 ≤215 6 5.88 102*120
GNRC165 120 150 132 165 6CTA8.3-G2 ≤210 6 8.3 114*135
GNRC200 140 175 160 200 6CTA8.3-G2 ≤210 6 8.3 114*135
GNRC225 160 200 180 225 6CTAA8.3-G2 ≤210 6 8.3 114*135
GNRC275 200 250 220 275 MTA11-G2A ≤210 6 10.8 125*147
GNRC313 220 275 250 313 NTA855-G1A ≤206 6 14 140*152
GNRC350 250 313 275 350 NTA855-G2 ≤207 6 14 140*152
GNRC400 280 350 310 400 NTA855-G4 ≤208 6 14 140*152
GNRC413 300 375 330 413 NTAA855-G7 ≤206 6 14 140*152
GNRC450 320 400 360 450 NTAA855-G7A ≤206 6 14 140*152
GNRC500 360 450 400 500 KTA19-G3 ≤203 6 18.9 159*159 
GNRC550 400 500 440 550 KTA19-G4 ≤203 6 18.9 159*159 
GNRC605 440 550 484 605 KTAA19-G6 ≤204 6 18.9 159*159 
GNRC625 450 563 500 625 KTAA19-G7 ≤204 6 18.9 159*159 
GNRC700 500 625 560 700 KTA38-G 206 12 37.8 159*159 
GNRC712 520 650 570 712 QSK19-G3 ≤206 6 19 159*159 
GNRC800 580 720 640 800 KTA38-GA 209 12 37.8 159*159 
GNRC825 600 750 660 825 KTA38-G2 210 12 37.8 159*159 
GNRC888 640 800 710 888 KTA38-G2B 210 12 37.8 159*159 
GNRC975 720 900 780 975 KTA38-G2A 210 12 37.8 159*159 
GNRC1075 800 1000 860 1075 KTA38-G5 ≤202 12 37.8 159*159 
GNRC1375 1000 1250 1100 1375 KTA50-G3  215 16 50.3 159*159
GNRC1650 1100 1375 1310 1650 KTA50-G8  215 16 50.3 159*159
GNRC1675 1200 1500 1340 1675 KTA50-GS8  215 16 50.3 159*159
GNRC1875 1350 1688 1500 1875 QSK60-G3  215 16 60 159*190
GNRC2063 1500 1875 1650 2063 QSK60-G3  215 16 60 159*190
GNRC2250 1600 2000 1800 2250 QSK60-G4  215 16 60 159*190
  Specification: detailed product description:
1) Rated output: 20kva 2000kva
2) Rated voltage:  220V/380V, 230V/400V, 240V/415V 3) Rated frequency: 50 / 60Hz
4) Power factor: 0.8.

Engine:  1)Cooling method: closed water cooling 2)Multi-cylinder in-line or veer engine, 4-stroke, direct injection 2)Starting method: electric start
3)Rated speed: 1,500 / 1,800rpm
  Alternator:
1) Brand:  Stamford,LeroySomer, Marathon,Engga 2) Rated output: 20kva to 2000kva 3) Rated voltage: 400 / 230V according to your requested
4) Rated Frequency: 50 / 60Hz
5) Power factor: 0.8
6) Phase: 3-phase, 4-wire
7) Connection: Y or other type connection
8) Rated speed: 1,500rpm / 1,800rpm
9) Excitation: harmonic excitation or phase compound or brushless
11) Voltage regulation: automatic
12) 1.0% voltage regulation (max.) in static conditions
13) Protection class: IP21-IP23 14)Connect with engine:Direct coupled with flywheel

Control panel:
1) The generator control panel is manufactured locally by
2) The panel is provided with:
a) Standard engine instrumentation
b) Voltmeter with selector switch
c) Ammeter with selector switch
d) Frequency meter
e) Current transformers
f) Instrument fuses duly wired and ferruled
g) Mcb of suitable rating with overload and short circuit protection
h) With AMF control panel or with ATS (automatic transfer system)
i) With EPA certification

 Warranty policy   Guarantee for one year or 1000 hours whichever reach first from ex-factory date. During the guarantee period, Genor will provide the free easy-damageable spare parts of diesel engine caused by our quality of production or raw material. After expiration, Genor provides cost spare parts maintenance of gensets.      

Send your message to this supplier

  • Mr. albert chen

  • Enter between 20 to 4,000 characters.