OEM Manufacturer ! Uk Imported Egine Diesel Generaor
- Payment Type:
- L/C, T/T
- Min. Order:
- 1 Set/Sets
- Min. Order:
- 1 Set/Sets
- Delivery Time:
- 25 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|---|
Supply Ability: | 200 Set/Sets per Month |
Payment Type: | L/C,T/T |
Product Description
Product Description
Specifications -Famous brand : Uk Imported engine
-Stamford alternator
-Reliable quality & factory price
-automatic start
-1 year war
OEM Manufacturer ! perkins diesel generaor Uk Imported power generator have earned a reputation for ease of service along with low costs of maintenance and repair and all Power part products carry an unequivocal 12-months warranty from date of purchase.
detailed product description:
1) Rated output: 20kva to 1250kva 2) Rated voltage: 220V/380V, 230V/400V, 240V/415V 3) Rated frequency: 50 / 60Hz
4) Power factor: 0.8.
Engine: perkins engine 1)Cooling method: closed water cooling 2)Multi-cylinder in-line or veer engine, 4-stroke, direct injection 2)Starting method: electric start
3)Rated speed: 1,500 / 1,800rpm
Alternator:
1) Brand: Stamford,LeroySomer, Marathon,Engga 2) Rated output: 20kva to 2000kva 3) Rated voltage: 400 / 230V according to your requested
4) Rated Frequency: 50 / 60Hz
5) Power factor: 0.8
6) Phase: 3-phase, 4-wire
7) Connection: Y or other type connection
8) Rated speed: 1,500rpm / 1,800rpm
9) Excitation: harmonic excitation or phase compound or brushless
11) Voltage regulation: automatic
12) 1.0% voltage regulation (max.) in static conditions
13) Protection class: IP21-IP23 14)Connect with engine:Direct coupled with flywheel

Control panel:
1) The generator control panel is manufactured locally by
2) The panel is provided with:
a) Standard engine instrumentation
b) Voltmeter with selector switch
c) Ammeter with selector switch
d) Frequency meter
e) Current transformers
f) Instrument fuses duly wired and ferruled
g) Mcb of suitable rating with overload and short circuit protection
h) With AMF control panel or with ATS (automatic transfer system)
i) With EPA certification
Standard accessories:
Standard control panel, damper, exhaust silencer, flexible pipe, battery and connecting wires, operation manual and document Optional accessories:
Intelligence control panel, water heater, oil-water separator battery charger, daily fuel tank, sound-resistant canopy, weather-resistant canopy and mobile trailer Warranty policy Guarantee for one year or 1000 hours whichever reach first from ex-factory date. During the guarantee period, Genor will provide the free easy-damageable spare parts of diesel engine caused by our quality of production or raw material. After expiration, Genor provides cost spare parts maintenance of gensets

-Stamford alternator
-Reliable quality & factory price
-automatic start
-1 year war
OEM Manufacturer ! perkins diesel generaor Uk Imported power generator have earned a reputation for ease of service along with low costs of maintenance and repair and all Power part products carry an unequivocal 12-months warranty from date of purchase.

Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRP10 | 7 | 9 | 8 | 10 | 403D-11 | ≤252 | 3 | 1.131 | 77*81 |
GNRP15 | 10 | 13 | 12 | 15 | 403D-15 | ≤264 | 3 | 1.496 | 84*94 |
GNRP23 | 16 | 20 | 18 | 23 | 404D-22 | ≤243 | 4 | 2.216 | 84*100 |
GNRP33 | 24 | 30 | 26 | 33 | 1103A-33G | ≤210 | 3 | 3.3 | 105*127 |
GNRP50 | 36 | 45 | 40 | 50 | 1103A-33TG1 | ≤212 | 3 | 3.3 | 105*127 |
GNRP65 | 48 | 60 | 52 | 65 | 1103A-33TG2 | ≤211 | 3 | 3.3 | 105*127 |
GNRP73 | 52 | 65 | 58 | 73 | 1104A-44TG1 | ≤207 | 4 | 4.4 | 105*127 |
GNRP88 | 64 | 80 | 70 | 88 | 1104A-44TG2 | ≤213 | 4 | 4.4 | 105*127 |
GNRP103 | 75 | 94 | 82 | 103 | 1006TG1A | ≤210 | 6 | 5.99 | 100*127 |
GNRP150 | 110 | 138 | 120 | 150 | 1006TAG | ≤205 | 6 | 5.99 | 100*127 |
GNRP165 | 120 | 150 | 132 | 165 | 1006TAG2 | ≤205 | 6 | 5.99 | 100*127 |
GNRP225E | 165 | 206 | 180 | 225 | 1306C-E87TAG3 | ≤220 | 6 | 8.7 | 117*136 |
GNRP250E | 180 | 225 | 200 | 250 | 1306C-E87TAG4 | ≤219 | 6 | 8.7 | 117*136 |
GNRP259E | 188 | 235 | 207 | 259 | 1306C-E87TAG5 | ≤221 | 6 | 8.7 | 117*136 |
GNRP275E | 200 | 250 | 220 | 275 | 1306C-E87TAG6 | ≤223 | 6 | 8.7 | 117*136 |
GNRP344E | 250 | 313 | 275 | 344 | 2206C-E13TAG2 | ≤201 | 6 | 14.6 | 137*165 |
GNRP388E | 280 | 350 | 310 | 388 | 2206C-E13TAG2 | ≤198 | 6 | 14.6 | 137*165 |
GNRP450E | 320 | 400 | 360 | 450 | 2206C-E13TAG3 | ≤201 | 6 | 14.6 | 137*165 |
GNRP500E | 360 | 450 | 400 | 500 | 2506C-E15TAG1 | ≤216 | 6 | 15 | 137*171 |
GNRP550E | 400 | 500 | 440 | 550 | 2506C-E15TAG2 | ≤211 | 6 | 15 | 137*171 |
GNRP625E | 450 | 563 | 500 | 625 | 2806A-E18TAG1A | ≤196 | 6 | 18.13 | 145*183 |
GNRP700E | 508 | 635 | 560 | 700 | 2806A-E18TAG2 | ≤203 | 6 | 18.13 | 145*183 |
GNRP800 | 580 | 725 | 640 | 800 | 4006-23TAG2A | ≤199 | 6 | 22.921 | 160*190 |
GNRP900 | 640 | 800 | 720 | 900 | 4006-23TAG3A | ≤200 | 6 | 22.921 | 160*190 |
GNRP1000 | 720 | 900 | 800 | 1000 | 4008-TAG1A | ≤206 | 8 | 30.561 | 160*190 |
GNRP1125 | 818 | 1022 | 900 | 1125 | 4008-TAG2A | ≤208 | 8 | 30.561 | 160*190 |
GNRP1375 | 1000 | 1250 | 1100 | 1375 | 4012-46TWG2A | ≤212 | 12 | 45.482 | 160*190 |
1) Rated output: 20kva to 1250kva 2) Rated voltage: 220V/380V, 230V/400V, 240V/415V 3) Rated frequency: 50 / 60Hz
4) Power factor: 0.8.
Engine: perkins engine 1)Cooling method: closed water cooling 2)Multi-cylinder in-line or veer engine, 4-stroke, direct injection 2)Starting method: electric start
3)Rated speed: 1,500 / 1,800rpm

1) Brand: Stamford,LeroySomer, Marathon,Engga 2) Rated output: 20kva to 2000kva 3) Rated voltage: 400 / 230V according to your requested
4) Rated Frequency: 50 / 60Hz
5) Power factor: 0.8
6) Phase: 3-phase, 4-wire
7) Connection: Y or other type connection
8) Rated speed: 1,500rpm / 1,800rpm
9) Excitation: harmonic excitation or phase compound or brushless
11) Voltage regulation: automatic
12) 1.0% voltage regulation (max.) in static conditions
13) Protection class: IP21-IP23 14)Connect with engine:Direct coupled with flywheel

Control panel:
1) The generator control panel is manufactured locally by
2) The panel is provided with:
a) Standard engine instrumentation
b) Voltmeter with selector switch
c) Ammeter with selector switch
d) Frequency meter
e) Current transformers
f) Instrument fuses duly wired and ferruled
g) Mcb of suitable rating with overload and short circuit protection
h) With AMF control panel or with ATS (automatic transfer system)
i) With EPA certification

Standard control panel, damper, exhaust silencer, flexible pipe, battery and connecting wires, operation manual and document Optional accessories:
Intelligence control panel, water heater, oil-water separator battery charger, daily fuel tank, sound-resistant canopy, weather-resistant canopy and mobile trailer Warranty policy Guarantee for one year or 1000 hours whichever reach first from ex-factory date. During the guarantee period, Genor will provide the free easy-damageable spare parts of diesel engine caused by our quality of production or raw material. After expiration, Genor provides cost spare parts maintenance of gensets