68kw to 500kw Volvo Open Type Generator
- Payment Type:
- L/C, T/T
- Min. Order:
- 1 Set/Sets
- Min. Order:
- 1 Set/Sets
- Delivery Time:
- 25 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Guangdong, China (Mainland) |
---|---|
Supply Ability: | 200 Set/Sets per Month |
Payment Type: | L/C,T/T |
Product Description
Product Description
Specifications Volvo Open Type Generator
1. ISO9001,ISO14001:2004,CE certificate
2. Volvo OEM
3 low fuel consumption
68kw to 500kw Volvo Open Type Generator Volvo generator have been widely used in large and small automobiles, heavy-duty trucks, engineering machineries and ships. Moreover, they are the ideal drive force of power generation sets. Volvo engines have high load capability as well as fast and reliable cold start performance.
Alternators Band for options: Stamford,LeroySomer, Marathon,Engga nsulation System: Class H Power Factor: 0.8 Phase/connecting method: 3 phase 4wire/Y type connection Excited type: Brushless, self excited or PMG Insulation: Class H Protection: IP21~IP23 Voltage regulation: AVR automatic control Altitude above sea level: ≤1000 meters Ambient air temperature: ≤40°C Relative air humidity: ≤ 90% Controller system 1.Standard control panel, including voltmeter, fequency meter, ampere meter,water temperature gauge, oil temperature gauge, oil pressure gauge, AMF control module,oil level indicator, emergency button,preheating button, battery voltage gauge, hours running counter for protection and tranfering. 2.It can be with ATS electric control cabinet, including circuit breaker, LCD or LED auto controller, indicating lamp, transfer switch,etc.. Automatic transfer switch (ATS) uses update technology, which can be automatic control for on-off electricity, remote monitoring, automatic parallel operation,etc… Factory Inspection, the test items before delivery are mainly as follows:
1. Each genset should be put into commission more than 4 hours totally. They are tested on idle load, fully load and 10% overload.
2. The noise level is be tested.
3. All the metres on the control panel should be tested
4. The appearance of the gensets and all of the label and nameplate shall be checked Standard Accessory Common steel base frame, Circuit breaker, Damper, Exhaust silencer, Flexible pipe, Battery connecting wires, Operation manual and document. Optional Accessory Battery, Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, Soundproof Canopy and Moving Trailer.
1. ISO9001,ISO14001:2004,CE certificate
2. Volvo OEM
3 low fuel consumption
68kw to 500kw Volvo Open Type Generator Volvo generator have been widely used in large and small automobiles, heavy-duty trucks, engineering machineries and ships. Moreover, they are the ideal drive force of power generation sets. Volvo engines have high load capability as well as fast and reliable cold start performance.
Genset Model | Prime Power | Standby Power | Engine | Fuel Consumption | Cylinder No. | Displacement | Bore X Stroke | ||
KW | KVA | KW | KVA | (g/kwh) | (L ) | (mm) | |||
GNRV95 | 68 | 85 | 76 | 95 | TD520GE | ≤213 | 4 | 4.67 | 108*130 |
GNRV110 | 80 | 100 | 88 | 110 | TAD531GE | ≤211 | 4 | 4.67 | 108*130 |
GNRV137 | 100 | 125 | 110 | 137 | TAD532GE | ≤204 | 4 | 4.67 | 108*130 |
GNRV165 | 120 | 150 | 132 | 165 | TAD731GE | ≤204 | 6 | 6.51 | 108*130 |
GNRV200 | 144 | 180 | 160 | 200 | TAD732GE | ≤204 | 6 | 6.73 | 108*130 |
GNRV225 | 160 | 200 | 180 | 225 | TAD733GE | ≤204 | 6 | 7.28 | 108*130 |
GNRV275 | 200 | 250 | 220 | 275 | TAD734GE | ≤200 | 6 | 7.28 | 108*135 |
GNRV350 | 250 | 312 | 280 | 350 | TAD941GE | ≤198 | 6 | 9.36 | 131*150 |
GNRV413 | 300 | 375 | 330 | 413 | TAD1241GE | ≤198 | 6 | 12.3 | 131*150 |
GNRV450 | 320 | 400 | 360 | 450 | TAD1242GE | ≤198 | 6 | 12.3 | 131*150 |
GNRV500 | 360 | 450 | 400 | 500 | TAD1640GE | ≤198 | 6 | 16.12 | 144*165 |
GNRV560 | 400 | 500 | 450 | 560 | TAD1641GE | ≤198 | 6 | 16.12 | 144*165 |
GNRV625 | 450 | 563 | 500 | 625 | TAD1642GE | ≤198 | 6 | 16.12 | 144*165 |
GNRV688 | 500 | 625 | 550 | 688 | TAD1643GE | ≤198 | 6 | 16.12 | 144*165 |
1. Each genset should be put into commission more than 4 hours totally. They are tested on idle load, fully load and 10% overload.
2. The noise level is be tested.
3. All the metres on the control panel should be tested
4. The appearance of the gensets and all of the label and nameplate shall be checked Standard Accessory Common steel base frame, Circuit breaker, Damper, Exhaust silencer, Flexible pipe, Battery connecting wires, Operation manual and document. Optional Accessory Battery, Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, Soundproof Canopy and Moving Trailer.