Energizer Rechargeable D Batteries and Charger
- Payment Type:
- L/C, T/T, D/P
- Incoterm:
- FOB, CFR, CIF
- Min. Order:
- 100 Piece/Pieces
- Min. Order:
- 100 Piece/Pieces
- Delivery Time:
- 30 Days
- Transportation:
- Ocean, Land
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | china |
---|---|
Productivity: | 2000, 000kvah/ Year |
Supply Ability: | 2000, 000kvah/ Year |
Payment Type: | L/C,T/T,D/P |
Incoterm: | FOB,CFR,CIF |
Certificate: | iso,UL,CE |
Transportation: | Ocean,Land |
LFP12180HR is a typical high rate discharge battery special designed for all kinds of high-power-ouput using application,
It is a non-spillable and sealed and Maintenance-free operation battery, with high quality and high reliability, good deep discharge recovery, low self-discharge ,etc. The battery apply solid copper terminals,tank-formed plates computer-aided design and manufacturing
Main features as follow:
* Standby use.
* High rate discharge construction.
* ISO9001, 14001, OHSMS 18001 certified.Energizer Rechargeable D Batteries and Charger* UL, CE, VdS Approved. UL recognized components under UL 1989 (file number MH28204 ).
*With isolated seal, it can be put in horizontal way, vertical way and side way, its safety and functions totally will not be affected.
* With special formula to manufacture lead calcium alloy as well as automatic progresses, gassing will be less.
* Long life, low self-discharge rate and high reliability.
* It has safety, low resistance so recharge is easy and energy output is more remarkable.
* Container material could be frame retardant ABS or PP with ranking UL 94V-0 by model.
* When it is used in safe surroundings, the battery is maintenance free, adding water is unnecessary and it can be recharged repeatedly.
* Batteries are strictly tested by computer charge/discharge system.
* Complies with IATA/ICAO Special Provision A67 for air transport.
* Classified per MG Amendment 27 as a non-hazardous material for water transport.
* Recognized by DOT as "Dry charge" 49 CFR 171-189 for surface transport.
Specifications
Nominal Voltage |
12 V |
||
Number of cell |
6 cells |
||
Capacity(10HR, 25℃) |
180 Ah |
||
Capacity(15min.rate, 25℃) |
640 Watts/cell |
||
Dimension |
Length |
494±2mm (19.45inch) |
|
Width |
206±2mm (8.11inch) |
||
Height |
209±2mm (8.23inch) |
||
Total Height |
235±2mm (9.25inch) |
||
Approx. Weight |
57kg (125.7lbs)±4% |
||
Terminal type |
T20/T11 |
||
Internal resistance (Fully charged, 25℃) |
Approx. 2.8mΩ |
||
Capacity affected by temperature (20HR) |
40℃ |
102% |
|
25℃ |
100% |
||
0℃ |
85% |
||
-15℃ |
65% |
||
Self-discharge (25℃) |
3 month |
Remaining Capacity: 91% |
|
6 month |
Remaining Capacity: 82% |
||
12 month |
Remaining Capacity: 65% |
||
Nominal operating temperature |
25℃±3℃(77℉±5℉) |
||
Operating temperature range |
Discharge |
-15℃~50℃(5℉~122℉) |
|
Charge |
-10℃~50℃(14℉~122℉) |
||
Storage |
-20℃~50℃(-4℉~122℉) |
||
Float charging voltage(25℃) |
13.50 to 13.80V Temperature compensation: -18mV/℃ |
||
Cyclic charging voltage(25℃) |
14.50 to 14.90V Temperature compensation: -30mV/℃ |
||
Maximum charging current |
54A |
||
Terminal material |
T20: Lead, T11: Copper |
||
Maximum discharge current |
1400A(5 sec.) |
||
Designed floating life(20℃) |
7~10 years |
◆ Absorbent glass mat technology;
◆ Recognized by UL & CE;
◆ ABS container.
Constant Current Discharge Characteristics (A, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
4h |
5h |
10h |
20h |
1.60V/cell |
626 |
417 |
343 |
275 |
195 |
145 |
118 |
65.8 |
47.2 |
38.0 |
33.0 |
18.5 |
9.80 |
1.65V/cell |
607 |
405 |
335 |
268 |
191 |
142 |
117 |
65.4 |
46.9 |
37.8 |
32.9 |
18.5 |
9.78 |
1.67V/cell |
598 |
399 |
333 |
264 |
188 |
140 |
115 |
65.2 |
46.8 |
37.7 |
32.8 |
18.5 |
9.77 |
1.70V/cell |
582 |
388 |
323 |
258 |
185 |
138 |
114 |
64.8 |
46.6 |
37.5 |
32.6 |
18.4 |
9.76 |
1.75V/cell |
557 |
371 |
312 |
249 |
180 |
134 |
111 |
63.8 |
46.3 |
37.3 |
32.40 |
18.3 |
9.70 |
1.80V/cell |
526 |
351 |
295 |
236 |
174 |
129 |
108 |
62.2 |
44.9 |
36.1 |
31.43 |
18.2 |
9.63 |
Constant Power Discharge Characteristics (Watt/cell, 25℃)
F.V/TIME |
5min |
10min |
15min |
20min |
30min |
45min |
60min |
2h |
3h |
4h |
5h |
10h |
20h |
1.60V/cell |
1139 |
785 |
663 |
530 |
376 |
280 |
228 |
128 |
93.0 |
74.9 |
65.4 |
37.0 |
19.6 |
1.65V/cell |
1105 |
761 |
647 |
518 |
368 |
274 |
225 |
127 |
92.4 |
74.4 |
65.1 |
36.9 |
19.6 |
1.67V/cell |
1088 |
749 |
643 |
509 |
364 |
271 |
223 |
127 |
92.1 |
74.2 |
64.9 |
36.9 |
19.5 |
1.70V/cell |
1060 |
730 |
623 |
498 |
357 |
266 |
219 |
126 |
91.8 |
73.9 |
64.6 |
36.8 |
19.5 |
1.75V/cell |
1014 |
698 |
602 |
481 |
348 |
259 |
215 |
124 |
91.1 |
73.4 |
64.2 |
36.6 |
19.4 |
1.80V/cell |
957 |
659 |
570 |
456 |
335 |
250 |
208 |
121 |
88.4 |
71.2 |
62.2 |
36.4 |
19.3 |
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
Typical Applications:
Alarm System
Cable Television
Communication Equipment
Control Equipment
Security System
Medical Equipment
UPS
Power Tools
Toys
Emergency Power System
Related Keywords