Hongrijia Depurate Facility Science & Technology Co.,Ltd.
Hongrijia Depurate Facility Science & Technology Co.,Ltd.
YUKA Coalescing Air Filter Remove Oil Vapor
  • YUKA Coalescing Air Filter Remove Oil Vapor
YUKA Coalescing Air Filter Remove Oil Vapor

YUKA Coalescing Air Filter Remove Oil Vapor

  • $589.99
    1-19 Piece/Pieces
  • $560.49
    ≥20 Piece/Pieces
Transportation:
Land, Ocean, Air, Express
Port:
Shenzhen, Guangzhou, Shanghai
Quantity:

Your message must be between 20 to 2000 characters

Contact Now
Basic Info
Basic Info
Place of Origin: China
Productivity: 20,000pcs per Month
Supply Ability: 20,000PCS Per Month
Payment Type: T/T,L/C
Incoterm: FOB,CFR,CIF,EXW
Certificate: CE
HS Code: 8421399090
Transportation: Land,Ocean,Air,Express
Port: Shenzhen,Guangzhou,Shanghai
Product Description
Product Description

What Compressed Air Contained?

Compressed air in industrial applications contains in 1Nmᶟ more than 100 million of polluting articles. Most of these particles are so small in dimension, less than 5 micron, that they cannot be intercepted by the standard intake Air Compressor Filter installed in the compressors. Such particles, mixed with water and oil vapour generated during compression, cause the early wear and tear of the appliances and consequently they are the cause of expensive interruptions of the production and remarkable increase maintain.

Selection right air filters will allow the best choice of the suitable equipment according to the quantity of air to be treated and the necessary filtration degree in order to increase and improve the performances of the whole system. 

Why Recommend YUKA Air Compressor Filter?

Material: Grade A Aluminum Alloy with die-casting technology

Filter Housing serve life: 15 years

Filter Housing with Corrosion Treatment : Inside and outside

Housing and filter with 100% air tightness test

Element material: Fiber glass, element server life: 6000~8000 hours

Filtration Efficiency: 99.99%

YD068 (4).png

 

 

With 7 Grades Filter Element

PF AO AA AX ACS AR AAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) Dust particles whose diameter more than 1μm can be removed Dust particles whose diameter more than 0.01μm can be removed

 

filter element

International test and measurement standard ISO12500>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
  parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the Coalescing Air Filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard,  and provide filter performance test report.

Filtration Grade  PF AO AA AX ACS AR AAR
Size of solid particles(ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm
Filtration performance of solid particles(ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+%
Filtration performance of oil(ISO12500-1) 50% 80+% 99.9+% 99.99+% - - -
Residual oil content(ISO12500-1) 5mg/m³ 0.6mg/m³ <0.01mg/m³ <0.001mg/m³ <0.004mg/m³ - -
                                                                              
Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.
Model Pipe size Flow Rate Dimenstion (mm)
L/S

m³/min

scfm W(Width)
D (Depth)
H(Height) A B C(clearance for housing)
YF010 RC1/2" 16.7 1.0 35.3 96 79 261 29 198 118
YF020 RC3/4" 25.0 1.5 53.0 96 79 261 29 198 118
YF030 RC1/2" 30.3 1.8 63.6 96 79 295 29 233 153
YF040 RC3/4" 33.3 2.0 71.0 96 79 295 29 233 153
YF060 RC3/4" 60.0 3.6 127.0 138 111 403 37 296 208
YF070 RC1" 83.3 5.0 177.0 138 111 503 37 396 303
YF080 RC1" 125.0 7.5 265.0 138 111 503 37 396 303
YF090 RC1-1/2" 166.7 10.0 353.1 174 142 736 58 607 469
YF100 RC2" 216.7 13.0 459.0 174 142 736 58 607 469
YF110 RC2-1/2" 283.3 17.0 600.0 174 142 1016 58 887 794
YF120 RC2" 316.7 19.0 671.0 174 142 1016 58 887 794
YF130 RC2-1/2" 416.7 25.0 883.0 220 184 793 74 649 514
YF140 RC2-1/2" 466.7 28.0 989.0 220 184 793 74 649 514
YF150 RC3" 683.3 41.0 1448.0 220 184 1050 74 906 764
YF160 RC3" 800.0 48.0 1695.0 220 184 1050 74 906 764
Technical requirements Maximum operating pressure: 10 barg   Operating temperature: 1.5°C~80°C.

 

Pressure Barg 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Psig 15 29 44 59 73 87 100 116 131 145 160 174 189 203 219 232
Correction 0.38 0.53 0.65 0.76 0.85 0.93 1.00 1.07 1.13 1.19 1.23 1.31 1.36 1.41 1.46 1.51

 

         

Accesa                                        

Accesories

air filter accessories

 

 

Success Cases
                                                                               
Yuka Aluminum Alloy Industry Air Filter with CE From China Factory (YF150)

 

Send your message to this supplier

  • Ms. YUKA

  • Enter between 20 to 4,000 characters.