LCD display Offline UPS with AVR
- Min. Order:
- 1
- Min. Order:
- 1
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | China |
---|---|
Supply Ability: | 50,000pcs/month |
Product Description
Product Description
LCD display Offline UPS with AVR
1: Offline UPS with AVR
2: Offline UPS with Overload and short circuit protection
3: CPU Control for Offline UPS
4: UPS Ports for RJ11/RJ12/RJ45/RS232/USB
Offline UPS - Offline UPS with Standby Function for Home and Office use
KEY FEATURES
1: Optional function
2: Line Surge Protection: RJ11/RJ12/RJ45, Communication Interface: RS232
3: Control mode: CPU controller
Function & Characteristic:
4: AVR, Overload and short circuit protection
5: Low battery alarm, LED status display
6: UPS Auto on when AC back, Night charging(optional)
Application: Home, Office
UPS MODEL | N400 | N500 | N650 | N800 | N1000 | N1200 | N1500 | ||
Nominal Voltage | 400VA/240W | 500VA/300W | 650VA/390W | 800VA/480W | 1000VA/600W | 1200VA/720W | 1500VA/900W | ||
Input | Voltage Range | 145~280VAC | |||||||
Frequency | 50/60Hz | ||||||||
Output | Voltage Range | 220VAC ± 10% | |||||||
Frequency | 50Hz ± 5% | ||||||||
Output Waveform | Square Wave | ||||||||
Transfer time | < 10ms | ||||||||
Battery | Type | Sealed free maintenance lead acid battery | |||||||
Capacity | 12V, 4AH *1PCS | 12V, 7AH *1PCS | 12V, 7AH *1PCS | 12V, 9AH *1PCS | 12V, 7AH *2PCS | 12V, 9AH *2PCS | 12V, 9AH *2PCS | ||
Recharge Time | 8 hrs to 90% of capacity full load discharge | ||||||||
Protection | Auto protect | ||||||||
Back-up time( Full load ) | 3~5 min | 5~7 min | 7~10 min | 6~8 min | 5~7 min | 8~10 min | 10-12min | ||
Function | Auto voltage output on AC mode, Auto shutoff if short circuit or overload | ||||||||
DB-9 port, communication software | Optional RS232, RJ11, RJ45, USB | ||||||||
Protection | AC mode | Fuse | |||||||
Short circuit | AC | Fuse | |||||||
Invert mode | Auto protect | ||||||||
Alarm | Alarm | Battery discharge | Alarm beeps every four seconds | ||||||
Low battery voltage | Alarm beeps every second | ||||||||
Overload | Alarm beeps continuously | ||||||||
Indicator light | Auto adjust | Green lighting: AC mode | |||||||
Battery Discharge | Red lighting: Battery mode | ||||||||
Environment | Operating temperature | 0C~40C | |||||||
Operating Humidity | 0-90% non-condensing | ||||||||
Noise | < 35dB (1 meter distance) | ||||||||
UPS Dimension (L× W× H) mm | 325*90*150 | 335*100*150 | 345*125*190 | ||||||
Net weight (N. W) | 4.50KG | 6.50KG | 6.80KG | 7.50KG | 11.00KG | 12.00KG | 13.00KG | ||
Gross weight (G. W) | 4.70KG | 6.70KG | 7.00KG | 7.70KG | 11.30KG | 12.30KG | 13.30KG |
Related Keywords